PFI (Power Factor Improvement Plant)


Power Factor is defined as the ratio of real power (KW) to the apparent power (KVA) and is cosine of the angle by which the current lags or leads the voltage.

Most frequently an industrial installation is fed from a high voltage system and comprises.
·        A transformer station.
·        Resistive loads, such as ovens, radiators, filament lamps, etc.
·        Inductive loads, such as transformer, motors, etc.

Among this larger load are inductive in nature. The inductive load is the cause of low Power Factor.

DISADVANTAGE OF LOW POWER FACTOR:

1.      Large KVA rating of equipment, KVA=KW/cosθ
2.      Greater conductor size, IL=KW/√3 VL cosθ
3.      Large copper losses, IL=KW/√3 VL cosθ
4.      Poor voltage regulative
5.      Larger line drop.
6.      Reduced handling capacity of system.

ADVANTAGE OF MOST ECOMOMICAL POWER FACTOR:

1.      Increase carrying capacity of the power station.
2.      Reduce billing of the system.
3.      Increase voltage.
4.      Good voltage regulation.
5.      Least conductor size.
6.      Least copper losses.
7.      Reduce KVA demand.

CHOOSE CAPACITY OF POWER FACTOR IMPROVEMENT PLANT:

CKVAR=KW× (tanθ1 – tanθ2)
Where: CKAVR= Capacitor KVAR required
KW = existing load
θ1= cos-1 (existing power factor)
θ2= cos-1 (desired power factor)
Check your billing meter if it is less than 0.96 then you are a looser.
Use the SR ENGINEERS PFI pay reduce bill and save your motor.






USE TABLE-1 TO IDENTIFY CAPACITY OF POWER FACTOR IMPROVEMENT PLANT:

COS#2
COS#1
0.98
0.99
1.00
0.547
0.609
0.750
0.80
0.521
0.581
0.724
0.81
0.495
0.555
0.698
0.82
0.469
0.529
0.672
0.83
0.443
0.503
0.646
0.84
0.417
0.477
0.620
0.85
0.390
0.450
0.593
0.86
0.364
0.424
0.467
0.87
0.337
0.397
0.540
0.88
0.309
0.369
0.512
0.89
0.281
0.341
0.484
0.90
0.253
0.313
0.456
0.91
0.223
0.283
0.426
0.92
0.192
0.252
0.395
0.93
0.160
0.220
0.363
0.94
0.126
0.186
0.329
0.95
0.089
0.149
0.292
0.96
0.048
0.108
0.251
0.97

0.060
0.203
0.98


0.143
0.99



1.00

voltage stabilizers for fridge


FOR USER:
Power supply voltage fluctuations now prevailing countrywide are potential dangers to the life of your fridge. SR ENGINEERS LTD has designed, developed and is manufacturing six Models of automatic voltage stabilizers with protector for fried to meet the special needs of your local power supply. Select one and save your Fridge.

APPLICATION:
·        IPES-600 uses for fridge up to 14 cft. Of any brand.
·        IPES-1000 uses for fridge up to 24 cft. Of any brand for deep fridge 14 of any brand.


Models of automatic voltage stabilizers for fridge:

     Model No.
Input Voltage Range
Output Voltage
     IPES-600
140V-270V
220V
     IPES-600
100V-270V
220V
    IPES-600
80V-270V
220V
    IPES-1000
140V-270V
220V
     IPES-1000S
100V-270V
220V
     IPES-1000W
80V-270V
220V

AVR, IVS (industrial voltage stabilizer)



 AVR, IVS (industrial voltage stabilizer)


FUNCTION & SURVICE:
·        Easy start function.
·        Wide AC input voltage range.
·        Output over voltage & short circuit protection.
·        Status indication LED display.
·        Low & High Voltage protection
·        UPS/Generator Compatibility.

More Features:
1.   Electronic controlled.
2.      LED/LCD status display.
3.      Generator Compatibility.
4.      Status indicator.
5.      Wide range regulation.
6.      Overload, short circuit protection.
7.      Auto-Manual regulation potion.
8.      Three phase balance system (Individual Phase Control).
9.      Voltage, Current indicator meter.
10.  Varies carries low inertia.
11.  Rust proof, air ventilated, powder coated as will as cable grouping facilities.






Technical Parameters:

PHASE
SINGLE PHASE
THREE PHASE
Model
IPES
IPES-3Φ
Capacity
1KVA-50KVA
3KVA-2000KVA
Input Voltage Range
140V-270V,120V-280V or 100V-280
300V-460V-260-480V
Output Voltage
220/230V / 240V AC
380V/400V/415V/440V
Frequency
50Hz
50Hz
Control System
Servo Control
Combined or Individual Phase Control.
Protection
Over Voltage, under voltage, over load,
short circuit, surge, sag, spike, transient protection
Over Voltage, under voltage, over load,
short circuit, surge, sag, spike, transient protection
Monitoring System
LED/LCD Display/Digital Display
LED/LCD Display
Correction Accuracy
±1% / ±3%
±1% / ±3%
Correction Speed
30V/sec or 50V/Sec
30V/Sec
Colling System
Oil immersed
Waveform Distortion
Negligible
Transient Suppression
Up to 800V Peak
Load Power Factor Effect
Nil
Enviroment Condition
4C~60C
Duty Cycle
95% Continuous
Humidity
Maximum 98%
Over Load Capacity
100% for 15 Sec